20 YEARS OF OPTICAL GAS IMAGING
From Handheld OGI to QOGI to ADGiLE: How FLIR Continues to Set the Global Standard
The Original Challenge Find What You Cannot See
For most of industrial history, gas leaks have had a frustrating advantage: they are often invisible.
Before optical gas imaging, inspectors typically relied on toxic vapor analyzers, better known as “sniffers.” The operator brings the probe close to a component, takes a reading, then moves to the next potential source. A refinery, compressor station, or production site may contain thousands of components that could leak, while most of them will not. Checking each one individually is rather like trying to find a draught in a house by moving your fingertip around every window frame.
On June 8, 2005, FLIR Systems introduced GasFindIR, the first commercially available optical gas imaging camera capable of detecting volatile organic compound emissions. The practical effect was transformative. Instead of testing suspected components one by one, an inspector could scan a much wider area, see where gas appeared to be escaping, and then trace the plume back to its source.
There was another important advantage: distance. Traditional contact methods may require an inspector to work close to the equipment, and potentially close to the gas itself. OGI can allow the first assessment to be made from farther away. Operators can inspect equipment 10 or 20 feet above them from ground level, rather than climbing toward a suspected source simply to discover whether it is leaking.
OGI did more than produce a more revealing inspection image; it allowed operators to survey more equipment at once, locate a source more quickly, and gather useful evidence without always having to stand next to the problem they were trying to find.


FLIR Systems released the GasFindIR camera in 2005.
The Leak Has Nowhere to Hide
—OGI turns invisible gas emissions into something operators can actually see.
From finding leaks To understanding emissions
Once operators could see leaks, the next question was almost inevitable: how much gas was actually escaping? A plume may look dramatic on screen, but appearance alone is a poor guide to leak rate. Its visibility depends on the gas itself, the temperature of the background, viewing angle, distance and environmental conditions. Two leaks that look similar may therefore represent quite different quantities of escaping product.
Quantitative optical gas imaging, or QOGI, added another layer of information. By combining cooled hydrocarbon OGI with algorithmic analysis, QOGI can estimate concentration pathlength and mass or volumetric leak rate. Instead of simply confirming that an emission exists, the operator can begin to put a number against it: grams per hour, liters per minute or another useful measure of flow.
That matters because maintenance is rarely short of things demanding attention. If an inspection finds ten leaks, a list of ten leaks gives the team ten jobs. If the data also shows that one of those leaks represents a far greater loss than the others, the same inspection begins to provide a priority order. The image has moved from detection towards decision-making.
The commercial implications can be substantial. Wyoming-based Jonah Energy used OGI to inspect around 150 facilities each month and approximately 1,700 wells over the course of a year. According to figures, fugitive emissions fell by 75% from 2010, while repair time dropped from 705 hours to 106. Labor costs fell from $58,369 to $7,500, and gas losses declined from approximately $348,000 to $20,500. Over six years, cumulative gas savings exceeded $5 million.
Those figures reveal something important about the economics of emissions. A methane leak is not only an environmental problem. It may also be a product that has already been extracted, processed, and transported at considerable expense before quietly escaping into the atmosphere. In this case, reducing emissions and reducing waste are not competing ambitions. They are often the same job.

Features such as High Sensitivity Mode improve gas detection.

Spectral filtering allows the camera to see the blow-leak from a methane tank.
When Regulators Learned to Trust the Picture
There is a familiar pattern in industrial technology. First something is novel. Then it becomes useful. Eventually somebody has to decide whether it is reliable enough to write into the rules.
OGI went through precisely that progression.
After GasFindIR entered the market in 2005, regulators began evaluating whether optical imaging could become part of formal leak detection and repair programs. The U.S. Environmental Protection Agency proposed an alternative OGI work practice in 2006, and a final rule took effect in 2008.
By 2016, the position had changed considerably. Under new oil and natural gas emissions standards, the EPA designated optical gas imaging as a Best System of Emission Reduction for methane from relevant sources.
That shift is significant because it marks the point at which an image stopped being merely useful to an inspector and became acceptable evidence within a regulated process.
OGI had moved from interesting technology to industrial method.
When the Environment Raises the Stakes
—The GFx320 was FLIR's first OGI camera designed and certified for use in hazardous areas.
The Camera That Does Not Clock Off
There is, however, a problem no handheld camera can completely solve.
Eventually, the person holding it leaves.
A scheduled inspection can give an excellent picture of a site at 10:17 on Tuesday morning. It tells you what was happening while the inspector was there. What it cannot tell you is whether a valve started leaking at 14:06, whether an intermittent release appeared during the night shift or whether a particular operating condition produced an emission for twenty minutes and then disappeared.
There may have been nothing wrong with the inspection. It simply occurred at the wrong time.
That distinction matters because industrial emissions do not work to maintenance calendars. Some are persistent; others are intermittent. Some depend on pressure, temperature, load or process conditions. If the event is not occurring while the camera is present, there may be nothing to record.
This is the inspection gap, and it is one reason the OGI story has gradually moved beyond the question of how well a person can inspect a facility towards another question altogether: what happens when nobody is looking?
Continuous monitoring changes the nature of the problem because the camera remains where the inspector cannot.
FLIR's ADGiLE™ platform brings together OGI hardware, analytics, processing, connectivity, and software in a single continuous monitoring workflow.
The system can be configured with uncooled technology for methane applications or cooled OGI cameras for broader hydrocarbon and volatile organic compound detection. Fixed and pan-tilt configurations allow coverage to be tailored to the layout and monitoring needs of each site.
It can tell you not only that something happened, but when it began, whether it persisted, and what the scene looked like around it.


ADGiLE combines the selected OGI camera and enclosure with edge processing, networking, software, licensing, and available services.
Twenty Years, Four Better Questions
The history of OGI can be understood without memorizing a single product name.
In 2005, the question was: Can I see the leak?
Once the answer became yes, the question changed to: Where is it coming from?
Quantification added another: How much is escaping?
And continuous monitoring now asks: What happens when nobody is there to see it?
That is perhaps the most interesting thing about OGI’s first twenty years. The underlying problem has hardly changed. Gas is still invisible, leaks are still undesirable and somebody still has to decide what to repair.
What has changed is the amount of information available before that decision is made.
The first OGI camera gave the leak a picture.
Everything since has been about making that picture more useful.